Not every cable harness does the same job.
A harness inside a machine on a production line has different reliability requirements from a harness inside a patient monitor or rail signalling system. That’s why IPC/WHMA-A-620 includes different product classes.
When engineers compare IPC 620 Class 2 vs Class 3, they’re deciding how reliable the assembly needs to be and what the consequences of failure would be.
For wire and cable harness assemblies, IPC/WHMA-A-620 defines the workmanship and acceptance criteria used during manufacture and inspection.
What’s the difference between IPC 620 Class 2 and Class 3?
The difference between IPC 620 Class 2 and Class 3 comes down to what happens when the harness stops working.
A harness inside a factory conveyor that fails means a stopped line and a call to maintenance. Applications like these are often specified to Class 2.
A harness inside a patient monitor that fails could have more serious consequences than one used on a production line. A harness inside a rail signalling system that fails could affect safe operation. Applications where failure carries greater risk are more likely to require Class 3 standards.
IPC/WHMA-A-620 defines three product classes:
- Class 1 covers general electronic products where long-term reliability is less critical.
- Class 2 covers products that are expected to perform reliably throughout their service life.
- Class 3 covers products where continued performance is critical because the consequences of failure are significantly greater.
In practical terms, Class 2 is commonly used for industrial equipment, automation systems, telecommunications equipment and test equipment.
Class 3 is more common in aerospace, defence, rail, critical energy infrastructure and life-critical medical devices.
Because the risk associated with failure is higher, Class 3 assemblies are built and inspected to more demanding acceptance criteria.
Which IPC class do I need?
A useful design-stage question is: What happens if this harness fails during operation?
If the answer is downtime, maintenance or replacement, Class 2 is generally appropriate.
If the answer involves safety, patient wellbeing, mission success or critical infrastructure, Class 3 is more likely to be required.
The IPC class should be agreed between the OEM, design team and manufacturing partner before production starts.
Specifying a higher class than the application requires can add unnecessary inspection and manufacturing costs. Specifying too low a class can create reliability risks that only become apparent once the product is in service.
What should you write on the drawing?
The manufacturer cannot work to the correct acceptance criteria if the class isn’t specified.
A drawing that simply says “wire harness assembly” leaves room for interpretation. A drawing that specifies IPC/WHMA-A-620 Class 2 or Class 3 tells everyone exactly which workmanship requirements apply.
For example:
- Manufacture and inspect to IPC/WHMA-A-620F Class 2
Or:
- Manufacture and inspect to IPC/WHMA-A-620F Class 3
The revision matters as well. If the customer is working to one revision and the manufacturer is working to another, misunderstandings can arise. Including both the class and revision helps ensure everyone is working to the same standard.
Why does the cable harness IPC class matter?
The IPC class affects more than the inspection report.
It influences how the assembly is manufactured, what inspectors are looking for and what will be accepted before shipment.
Two harnesses sitting side by side on a bench may look identical. The difference is the criteria used to build and inspect them.
A harness used to keep a production line running doesn’t face the same expectations as a harness used in a life-critical medical application. The IPC class ensures those differences are reflected in the manufacturing process.
Including the correct classification helps ensure:
- Accurate quotations
- Consistent quality expectations
- Appropriate inspection procedures
- Fewer disputes during acceptance
For engineers, it is one of the most important details to include on a drawing package because it defines what level of workmanship is required from the start.
IPC 620 vs IPC 610: what’s the difference?
These standards apply to different parts of a product.
IPC/WHMA-A-620 covers cable and wire harness assemblies, including crimps, terminations, splices, routing and bundling.
IPC-A-610 covers electronic assemblies, primarily PCBAs.
A simple way to remember it is:
- IPC 620 = cables, wires and harnesses
- IPC 610 = electronic assemblies and PCBs
Many products contain both, which means both standards may apply.
How can an IPC-trained harness manufacturer help?
An experienced manufacturer can often identify specification issues before production begins.
For example, a Class 3 requirement may be essential for one application, while another may achieve exactly the same functional outcome using Class 2 without introducing unnecessary cost.
Wireco manufactures cable assemblies and wire harnesses from its Congleton facility to IPC/WHMA-A-620 standards and has an in-house IPC trainer.
Reviewing the drawing at an early stage can help identify manufacturability concerns, confirm the suitability of the chosen IPC class and avoid costly changes later.
Need help specifying a cable harness?
Wireco manufactures custom cable assemblies and wire harnesses for customers across industrial, medical, telecommunications and renewable energy sectors.
Send us your drawing and specification and we’ll review the application, identify any manufacturability concerns and confirm whether the selected IPC class is appropriate before quoting.
Not sure whether Class 2 or Class 3 is appropriate for your application? Get in touch.